If you have ever walked past a radiator, felt the bottom and found it toasty whilst the top stays stubbornly cool, you have met trapped air. It is one of the most common complaints we hear from homeowners, and happily it is also one of the easiest things to put right yourself.
Your heating system circulates water, but it also contains air. Over time, small amounts of air find their way in, and because air is lighter than water it rises to the highest point it can reach — usually the top of an upstairs radiator. That pocket of air pushes the hot water aside, so the radiator simply cannot heat that section. No amount of turning the thermostat up will shift it.
Look out for these tell-tale signs:
It is worth knowing one thing before you start. If a radiator is cold at the bottom and warm at the top, that is not air — that is usually sludge or debris settled inside, and bleeding will not help. That job needs a different approach, which we will come to shortly.
A little preparation makes this a ten-minute job rather than a stressful one. Switch the heating off at the controls and let the system cool for at least half an hour. Bleeding releases hot water, and there is no sense in risking scalded fingers or a soaked carpet.
Gather together:
Pop the towel underneath the valve and keep the bowl close. The water that comes out is usually dark and can stain pale carpets, so protect the floor before you touch anything.
Work through the house in a sensible order rather than jumping around. Start on the ground floor and move upwards, and on each floor begin with the radiator furthest from the boiler. Air naturally wants to rise, so this sequence lets it travel out rather than being pushed back into the system.
Bleeding removes water as well as air, so the pressure in your system will drop. On a combi boiler or any sealed system, check the gauge on the front of the boiler. When the system is cold it should normally sit between 1 and 1.5 bar.
If it has fallen below 1 bar, top it up using the filling loop — the braided hose with two small valves underneath the boiler. Open one valve slowly, watch the gauge, and close it as soon as you reach the right reading. Never leave the loop open, and never take the pressure above 2 bar. If your boiler keeps losing pressure, that is a separate fault and worth a call to an engineer.
Older open-vented systems are different. They are fed from a small tank in the loft, so they tend to top themselves up automatically. If yours needs bleeding constantly, check that tank is filling properly.
Sometimes you bleed a radiator perfectly and it still runs cold. A few likely culprits:
If any of these sound familiar, it is worth having the system looked at rather than simply bleeding the same radiator every month.
Bleed your radiators once a year, ideally in early autumn before you start leaning on the heating. Check the boiler pressure every few weeks through the winter — it takes seconds and catches small problems early. If you are bleeding the same radiator more than twice a season, make a note of it and get it investigated.
Ten minutes with a radiator key each year is one of the best value jobs in the house. Even heat, a warmer home, and a boiler that is not working harder than it needs to — all for the price of a key and a bit of patience.